Engineering solutions for electrical & industrial assetsinfo@techno-master.co+20 1145008761
MEGGER · ODEN AT

Megger ODEN AT Primary Current Injection Test System

Techno Master offer you Megger ODEN AT Primary Current Injection Test System in Egypt.

A powerful primary injection test system for protective relay equipment and circuit breakers, also used for current transformer turns ratio testing and other applications requiring high variable currents — a control unit with one, two or three portable current units (S, X or H versions).

Megger ODEN AT Primary Current Injection Test System

Official Megger product photography

Primary injection testing of relays, breakers and current transformers

Testing capabilities

  • Primary injection testing of protective relays and circuit breakers, plus CT turns ratio testing
  • Powerful measurement section displays turns ratio, time, voltage and current; a second channel measures an additional current or voltage
  • CT turns ratio, impedance, resistance, power, power factor (cos φ) and phase angle calculated and shown directly
  • Polarity testing with phase displacement display and clearly marked output polarities
  • Heat runs with continuous current or programmable intervals, with times in minutes and hours for long-term testing
  • Automatic recloser and sectionalizer testing — operating limits, partial and total times, operations before lockout, user-selectable reclosing sequences
  • Ground grid and safety-ground integrity testing by current injection and voltage drop measurement
  • Fast-acting hold function freezes short-duration readings on the digital display
Manufacturer-published capabilities. Available tests depend on the selected configuration and accessories. Confirm suitability, availability and pricing with our technical team.

Technical specifications

Manufacturer / modelMegger / ODEN AT
SystemControl unit plus one, two or three current units — S, X (additional 30/60 V output) or H (higher current) versions
ApplicationsPrimary injection of relays and breakers; CT turns ratio, burden and polarity; heat runs; reclosers and sectionalizers; ground grid integrity
MeasurementTurns ratio, time, voltage, current; second channel for additional current or voltage; impedance, resistance, power, cos φ and phase angle calculated
Turns ratio displayDirect as nominal value (e.g. 1000/5) — no further calculation; secondary burden presented in VA
Hold functionFast-acting hold freezes short-duration readings when stop input signal arrives or injection stops
PortabilityAll parts portable; quickly assembled and connected
Manufacturer product information

Downloads

Download Datasheet

Related site services

CT / VT Testing

Verify instrument transformer performance for reliable measurement and protection.

Explore Service

Circuit Breaker Testing

Assess the electrical and mechanical performance of critical switching assets.

Explore Service

Other Electrical Testing

Discuss a testing scope tailored to your electrical infrastructure and industrial assets.

Explore Service

Related technical resources

Related equipment

Hipotronics HVT-DI Portable AC Hipot Tester

Hipotronics HVT-DI Portable AC Hipot Tester

A portable digital AC hipot tester series (30 kV, 60 kV and 100 kV models) for testing the insulation strength of switchgear, vacuum interrupters, breakers, bucket trucks, aerial platforms and live-line tools.

View Details
Eaton Sefelec 1000-M Megohmmeter

Eaton Sefelec 1000-M Megohmmeter

A programmable insulation resistance tester for production quality control and incoming inspection, offering adjustable DC test voltage, automatic range selection and sequenced testing with stored results.

View Details

The right solution starts with a conversation.

Discuss your testing equipment, site services or calibration requirements with our technical team.